Gap Between Roof Sheathing And Batt Insulation

Insulating Walls With No Sheathing Wall Insulation Rigid Foam Insulation Exterior Wall Insulation

Insulating Walls With No Sheathing Wall Insulation Rigid Foam Insulation Exterior Wall Insulation

Unvented Attic Insulation Building America Solution Center Roof Insulation Roof Cladding Patio Roof

Unvented Attic Insulation Building America Solution Center Roof Insulation Roof Cladding Patio Roof

Steel Stud Parapet Old Timer Wood Blocking And A Cant Anchored To The Structural Deck Restrain Architecture Details Roof Construction Architecture Building

Steel Stud Parapet Old Timer Wood Blocking And A Cant Anchored To The Structural Deck Restrain Architecture Details Roof Construction Architecture Building

Rigid Xps Foam Insulation Was Installed Outside Of The Roof Sheathing To Allow For The Exposed Rafters And To C Sunroom Addition Roof Sheathing Exposed Rafters

Rigid Xps Foam Insulation Was Installed Outside Of The Roof Sheathing To Allow For The Exposed Rafters And To C Sunroom Addition Roof Sheathing Exposed Rafters

Attic View Roof Deck Rafters Lookouts Fascia And Plywood Soffit Fascia Home Maintenance Roof

Attic View Roof Deck Rafters Lookouts Fascia And Plywood Soffit Fascia Home Maintenance Roof

10 Tips To Improve Wall Insulation Home Insulation Diy Insulation Wall Insulation

10 Tips To Improve Wall Insulation Home Insulation Diy Insulation Wall Insulation

10 Tips To Improve Wall Insulation Home Insulation Diy Insulation Wall Insulation

Batts secured to the deck with insulation hangers between top chords or more commonly tension cables secured at the ridge and eaves with eye hooks to prevent fall out.

Gap between roof sheathing and batt insulation.

If you use air permeable insulation and it is not in direct contact with the air barrier in this case the plywood roof deck you will experience convective. Apply a 2 inch layer of spray foam insulation r 10 to r 12 directly to the interior surface of the roof sheathing. Unless you have at least a 1 gap between the roof deck and roxul with both ridge soffit venting putting putting foil facers on the interior side is going to create a moisture trap. Leave gaps between panels you need a gap on the roof so your room could breathe.

Batts should cover the top plate of the exterior wall but not block the venting. To maintain airflow leave a space of 38 to 50 mm 1 1 2 to 2 in between the top of the insulation and the underside of the roof sheathing. The only way you can make venting work on this type of roof is if you can maintain a gap of at least 6 inches between the top of your insulation and the underside of your roof sheathing and if you can cut a 2 ft. You can then apply batt insulation around the foam without worrying too much about the air space.

Generally spray foams have to be applied by a professional. Shingles roofing felt stackups are on the boundary between class i class ii vapor retardency when dry at about 0 1 perms and when the roof is wet there is. Hole in the roof sheathing near the center of your roof so that you can install a doghouse above the roof to act as a vent outlet. This will keep the surface warm and help minimize condensation.

Here is a fact.

10 Tips To Improve Wall Insulation Home Insulation Interior Wall Insulation Insulation

10 Tips To Improve Wall Insulation Home Insulation Interior Wall Insulation Insulation

Related Image Standing Seam Metal Roof Metal Roof Construction Metal Roof

Related Image Standing Seam Metal Roof Metal Roof Construction Metal Roof

If You Have 6 Thick Walls It May Be Possible To Install 4 Of Closed Cell Spray Foam In The Wall Cavity And Then R Home Construction Roof Design Mansard Roof

If You Have 6 Thick Walls It May Be Possible To Install 4 Of Closed Cell Spray Foam In The Wall Cavity And Then R Home Construction Roof Design Mansard Roof

Eave Baffle Vent And Continuation Panel For Cathedral Ceilings Cathedral Ceiling Metal Roof Roof

Eave Baffle Vent And Continuation Panel For Cathedral Ceilings Cathedral Ceiling Metal Roof Roof

Source : pinterest.com